OpenIFBCloses Dec 3, 2026, 2:00 PM CT

McDuffie Main 25 kV Switchgear Upgrade REBID

Alabama Port AuthorityMobile, Alabama#Project 11712, Task 2

The Alabama Port Authority (APA) is soliciting bids for the McDuffie Main 25 kV Switchgear Upgrade REBID in Mobile, Alabama. This project involves the replacement of existing 25 kV main switchgear. The scope includes manufacturing and delivering the specified equipment, with the bidder responsible for lead times and liquidated damages for delays. APA will award the contract to the bidder offering the best value, considering cost, solution, and delivery schedule. Proposals must be valid for 60 calendar days. Key deadlines include a Questions Deadline of Wednesday, November 25, 2026, at 4:00 pm CST, and a Bid Submittal Deadline of Thursday, December 3, 2026, at 2:00 pm CST. Bids must be submitted via courier or hand delivery; faxed or electronic bids will not be accepted. A Bid Bond of 5% of the proposal, not to exceed $10,000, is required. Contractors must certify compliance with the Beason-Hammon Alabama Taxpayer and Citizen Protection Act and provide E-Verify enrollment evidence. All individuals working on-site must possess a TWIC card, APA badge, and APA vehicle decal. The switchgear will be a 25-kV class, NEMA 3R outdoor-rated, Main-Tie-Main configuration with specific features including vacuum circuit breakers, fused feeder compartments, and integrated power monitoring and control sections. A performance bond of 100% of the contract value will be required from the successful bidder.

On PublicBidSearch: the original bid posting, 1 bid document and the agency contact (name and email) for this bid.

Open Original Bid Source Pro

Contact

Agency contact for this bidName and email — included with ProPro

Overview

Due
Dec 3, 2026, 2:00 PM CT
Time stated in bid documents
Dec 3, 2026, 2:00 PM Central Time
Bid bond
5%
Performance bond
Required
Submission
courier, hand delivery
Documents analyzed
1

Scope of work

  • Replace existing 25 kV main switchgear lineup.
  • Manufacture and deliver specified equipment to McDuffie Coal Terminal.
  • Includes SEL relays, SEL-735 meters, and integrated communications section.
  • Bidder responsible for lead times, factory testing, and spares.

Steps to Bid

  1. 1

    Submit questions in writing to the Engineer. by Nov 25, 2026, 4:00 PM

    Questions must be submitted by Wednesday, November 25, 2026, at 4:00 pm CST.

  2. 2

    Submit sealed bid proposals via courier or hand delivery. by Dec 3, 2026, 2:00 PM

    Bid proposals must be received no later than 1:30 P.M. on Thursday, December 3, 2026, via courier to 1400 Alabama State Docks Blvd., Room 216, Administration Building, Mobile, AL 36602. Hand delivery is accepted from 1:45 P.M. to 2:00 P.M. on Thursday, December 3, 2026, to the Alabama Port Authority International Trade Center Lobby, 250 North Water Street, Mobile, AL. Faxed or electronic bids will not be accepted.

  3. 3

    Execute Contract and furnish required bonds. by Dec 13, 2026, 2:00 PM

    Within ten (10) calendar days from the date of written notice of intent to award.

What you'll need

Bid security

Required

The performance bond shall be 100% of the contract value.

Award method

APA will select the bidder whose proposal is the best value based on a combination of cost, value of proposed solution, and delivery schedule.

Submission

Courier, Hand delivery

How to submit

One copy of the Proposal, acknowledgement of addenda, Certificate of Compliance, and Delivery schedule should be placed in a sealed envelope with the bidder’s name, the project name and number, and the time and date of bid opening shown on the outside. All submissions, including hand-delivered packages, US Postal Service express mail, or private delivery service must be delivered to the specified address. Neither fax nor email submissions will be accepted. Respondents are responsible for effective delivery by the above deadline, and late submissions will be rejected without opening and returned to the sender.

In person/mail: Alabama Port Authority, Pete Olivero, P.E., Sr. Facilities Engineer, 1400 Alabama State Docks Boulevard, Administration Building, Suite 216, Mobile, AL 36602

Pursuit snapshot

Pro
  • Go / no-go verdict on every requirement
  • 10 watch-outs that disqualify bidders
Unlock with Pro — $20/mo

Cancel anytime · no card to browse

Project details

Liquidated damages will be applied based on the provided delivery schedule. Specifications, proposal forms, bond forms, and plans are available on the Alabama Port Authority website at [link available with Pro]. The project requires bidders to supply a delivery schedule, breakout drawing lead time, manufacturing lead time, and estimated shipping time. Bidders must state if they perform factory acceptance testing, if their switchgear is one continuous line-up or two, and provide a complete Bill of Material (BOM). They must also state if all material and components are included in the bus tie section for programming, provide a list of spares, and clearly state their control power (125VDC, 48VDC, or combination). Bidders must also confirm if they meet the station battery requirement of 10-hour full-load reserve. Liquidated damages for delivery delays are $1,200.00 per day. Subsequent to final acceptance, contractors must provide an affidavit of payment of claims, a waiver of claims upon final payment, a two-year written guarantee, and assign warranties for incorporated items. The switchgear shall be a factory-assembled, metal-enclosed medium-voltage switchgear lineup arranged in a Main-Tie-Main configuration with two main vacuum circuit breakers, one tie vacuum circuit breaker, eight fused feeder compartments, and one spare compartment. It will be rated 25-kV class, for outdoor installation, NEMA 3R. The assembly shall be designed, manufactured, and tested in accordance with ANSI, IEEE, NEMA, and applicable NEC requirements. The lineup shall include a dedicated Power Monitoring and Controls Section Battery housing the 48 VDC station battery system and a Network Section for communications equipment. The switchgear enclosure must be suitable for outdoor operation in a coal terminal environment, providing protection against coal dust, moisture, corrosion, marine environment, and ultraviolet exposure. It must meet ANSI/IEEE C37.20.2 or C37.20.3 standards, NEMA 3R outdoor enclosure, and have corrosion-resistant hardware and exterior finish. The control compartment must be physically isolated from medium-voltage compartments by grounded metal barriers and include minimum 42U rack or panel mounting space. Cable termination space shall accommodate all feeders with sufficient depth and clearance. The main and tie bus shall be rated 1200 amperes continuous. The two main incoming breakers and the tie breaker shall be drawout vacuum circuit breakers, 25-kV class, 1200A frame, electrically operated with stored-energy mechanisms. Eight fused feeder compartments shall be furnished, each with a load-interrupter switch and current-limiting power fuses, and a dedicated SEL-735 Power Quality Meter. One spare compartment shall be furnished, fully equipped for a future feeder assembly. The Power Monitoring and Controls Section shall be isolated from medium-voltage compartments and designed to minimize arc-flash exposure. The enclosure shall have a thermostatically controlled, filtered ventilation system. The Network Communications Compartment shall contain a SEL-735 Power Quality Meter, Fiber Optic Patch Panel, and a Managed Industrial Ethernet Switch. The tie device shall be a drawout vacuum circuit breaker. The switchgear shall be furnished with all necessary current transformers, voltage transformers, metering devices, communications equipment, and protective relays. The system shall support IEC 61850 MMS, Modbus TCP/IP, DNP3 over Ethernet, and SNTP. A Factory Acceptance Test (FAT) is required, with pricing for a witnessed FAT to be included as a separate line item. The supplier shall furnish a spare parts package for the switchgear lineup. Documentation requirements include general layout, network architecture, schematic and wiring diagrams, installation/operation/maintenance instructions, and as-built drawings.

Key dates

Questions due
Nov 25, 2026, 4:00 PM Central Time
Bids due
Dec 3, 2026, 2:00 PM CT

Documents

  • 11712-02-McDuffie-Main-Switchgear-ReBid-Documents.pdf48 pages

See all documents · Download with Pro