CryoPlatform Coldhead Exchange, Testing, and Calibration for 600 MHz NMR Cryogenic Probe
National Institutes of Health — NATIONAL INSTITUTES OF HEALTH OLAOMaryland#75N98027Q00098
The work is required to maintain continuous operation of 24/7 NMR spectrometers at the NHLBI Laboratory for Molecular Biophysics. The coldhead must be compatible with existing Bruker systems, communicate with the proprietary CRCO, and meet specific cooling and temperature specifications.
On PublicBidSearch: the original bid posting, 1 bid document and the agency contact (name, email and phone) for this bid.
Contact
Agency contact for this bidName, email and phone — included with ProProOverview
- Due
- Nov 30, 2026
- Time stated in bid documents
- Nov 30, 2026, 7:00 AM Eastern Time
- Submission
- Documents analyzed
- 1
Scope of work
- Replace CryoPlatform coldhead on 600 MHz NMR cryogenic probe
- Perform OEM testing and calibration of CryoPlatform system and cryogenic probe
- Ensure compatibility with existing Bruker CryoController and cryogenic probe platform
Steps to Bid
- 1
Register in Official linkPro and obtain a UEI and TIN
- 2
Ensure active SAM registration and compliance with FAR 52.212-4 and 52.204-7
What you'll need
Submission
NAICS
334516
Pursuit snapshot
Pro- Go / no-go verdict on every requirement
Cancel anytime · no card to browse
Project details
The acquisition is conducted under FAR 12.603, Streamlined Solicitation for Commercial Products or Commercial Services, and is not expected to exceed the simplified acquisition threshold. The coldhead exchange is required to maintain continuous operation of the 600 MHz and 800 MHz NMR spectrometers in the National Heart, Lung, and Blood Institute (NHLBI) Laboratory for Molecular Biophysics, which operate 24/7 to study protein-protein, protein-peptide, and protein-drug interactions. The existing cryocooler coldhead must be replaced every 10,000 hours of runtime to prevent system failure and loss of cryogenic temperatures. The replacement unit must be compatible with existing Bruker cryogenic probe platform equipment (600 MHz / 800 MHz NMR instruments) with no physical or software modifications. It must communicate directly with the proprietary Bruker CryoController (CRCO), provide 1.0 W cooling capacity at 4.2K, achieve a minimum temperature below 3.5K at the second stage, and operate on a 2-stage Gifford-McMahon refrigeration cycle. The delivery location is NIH/NHLBI, Building 50, Room B204, 9000 Rockville Pike, Bethesda, MD 20892.
Key dates
- Bids due
- Nov 30, 2026
Documents
- Sol_75N98027Q00098.pdf6 pages
More from this agency
- Liquid Nitrogen Gas (LN2) Service for Clinical Biorepository Freezers at NCI Surgery Branch T30 Cell Production Facility · closes Nov 30, 2026
- SEED Company Showcase Participation at Biotech Showcase 2027 for NIH SBIR/STTR Recipients · closes Nov 30, 2026
- Maintenance and Support for Leica Bond RXm Autostainer — Silver Service Package · closes Dec 1, 2026
- Medical Pathological Waste (MPW) Boxes with Bags · closes Dec 1, 2026
- SNOMED CT and Related Services · closes Dec 1, 2026
More open bids in Maryland
- Request for Qualifications — Snow and Ice Removal Services for RDA-Owned Properties
- Resurfacing of Roadways at Various Locations in Montgomery and Prince George's Counties · closes Jan 7, 2027
- Guardianship Forensic Auditing Services · closes Nov 30, 2026
- Bearing Sleeve, Generator Bearing, Sleeve for Main Propulsion Generator on U.S. Coast Guard WAGB Vessels · closes Dec 3, 2026
- Indoor Parking Space Rental for Government-Leased Vehicles — Chicago Field Division, SSA OIG · closes Dec 9, 2026
Closing soon in Maryland
- FPL1000 Signal and Spectrum Analyzer · closes Nov 30, 2026
- Propulsor Device Machining · closes Dec 1, 2026
- Academic Faculty Management Software Platform · closes Dec 2, 2026
- 69/25 kV Hailem School Road Substation #5 Construction · closes Dec 2, 2026
- Sequencing Kits for Long-Read RNA Sequencing Research · closes Dec 4, 2026