CryoPlatform Coldhead Exchange, Testing, and Calibration for 600 MHz NMR Cryogenic Probe

National Institutes of Health — NATIONAL INSTITUTES OF HEALTH OLAOMaryland#75N98027Q00098

The work is required to maintain continuous operation of 24/7 NMR spectrometers at the NHLBI Laboratory for Molecular Biophysics. The coldhead must be compatible with existing Bruker systems, communicate with the proprietary CRCO, and meet specific cooling and temperature specifications.

On PublicBidSearch: the original bid posting, 1 bid document and the agency contact (name, email and phone) for this bid.

Open Original Bid Source Pro

Contact

Agency contact for this bidName, email and phone — included with ProPro

Overview

Due
Nov 30, 2026
Time stated in bid documents
Nov 30, 2026, 7:00 AM Eastern Time
Submission
email
Documents analyzed
1

Scope of work

  • Replace CryoPlatform coldhead on 600 MHz NMR cryogenic probe
  • Perform OEM testing and calibration of CryoPlatform system and cryogenic probe
  • Ensure compatibility with existing Bruker CryoController and cryogenic probe platform

Steps to Bid

  1. 1

    Register in Official linkPro and obtain a UEI and TIN

  2. 2

    Ensure active SAM registration and compliance with FAR 52.212-4 and 52.204-7

What you'll need

Submission

Email

NAICS

334516

Pursuit snapshot

Pro
  • Go / no-go verdict on every requirement
Unlock with Pro — $20/mo

Cancel anytime · no card to browse

Project details

The acquisition is conducted under FAR 12.603, Streamlined Solicitation for Commercial Products or Commercial Services, and is not expected to exceed the simplified acquisition threshold. The coldhead exchange is required to maintain continuous operation of the 600 MHz and 800 MHz NMR spectrometers in the National Heart, Lung, and Blood Institute (NHLBI) Laboratory for Molecular Biophysics, which operate 24/7 to study protein-protein, protein-peptide, and protein-drug interactions. The existing cryocooler coldhead must be replaced every 10,000 hours of runtime to prevent system failure and loss of cryogenic temperatures. The replacement unit must be compatible with existing Bruker cryogenic probe platform equipment (600 MHz / 800 MHz NMR instruments) with no physical or software modifications. It must communicate directly with the proprietary Bruker CryoController (CRCO), provide 1.0 W cooling capacity at 4.2K, achieve a minimum temperature below 3.5K at the second stage, and operate on a 2-stage Gifford-McMahon refrigeration cycle. The delivery location is NIH/NHLBI, Building 50, Room B204, 9000 Rockville Pike, Bethesda, MD 20892.

Key dates

Bids due
Nov 30, 2026

Documents

  • Sol_75N98027Q00098.pdf6 pages

See all documents · Download with Pro

More from this agency

More open bids in Maryland

Closing soon in Maryland