Repair of PUMP HIGH PRESSURE
Dept of the Navy — NAVSUP WEAPON SYSTEMS SUPPORT MECHPennsylvania#N0010427QJA33
The U.S. Navy is soliciting bids for the repair of a PUMP HIGH PRESSURE (CAGE: 0UTW4, Ref. No.: 905-09254-000). The repair must comply with MIL-STD-130 marking standards and approved repair procedures. A 118-day RTAT is required from physical receipt at the contractor’s facility. GSI is mandatory. Freight is FOB Origin. The Government may exercise an option to increase quantity. A price reduction per unit per month will be applied for inexcusable delays. The contractor must provide repair cost, new unit price, and delivery lead time. The contract will be awarded bilaterally upon acceptance.
On PublicBidSearch: the original bid posting and the agency contact (name and email) for this bid.
Contact
Agency contact for this bidName and email — included with ProProOverview
- Due
- Dec 4, 2026
- Time stated in bid documents
- Dec 4, 2026, 3:30 PM Eastern Time
- Submission
- electronic portal
- Required submission items
- 8 items · full checklist with Pro
Steps to Bid
- 1
Verify the NSN, part number, and nomenclature of the PUMP HIGH PRESSURE before submitting a quote.
- 2
Ensure your company is capable of meeting the required RTAT of 118 days from physical receipt at your facility.
- 3
Prepare a quote including unit price, total price, RTAT, and any capacity constraints if not meeting the required RTAT.
- 4
If the item has not been previously purchased by NAVSUP WSS or if pricing has increased, provide the NSN of a similar item or previous NSN if an upgrade.
- 5
If the item has been sold commercially or to another buying activity, provide a redacted copy of your invoice.
- 6
If pricing is not in line with historical pricing, provide the basis for your pricing.
- 7
If the asset is determined BR or BER, provide documentation of incurred T&E costs and the basis for the T&E fee.
- 8
Submit the completed quote via the Official linkPro portal by the due date. by Dec 4, 2026, 3:30 PM
What you'll need
Submission
Electronic portal
NAICS
333914
How to submit
Submit via the Official linkPro portal. Include all required information in the quote, including unit price, total price, RTAT, and any capacity constraints. Provide supporting documentation if applicable.
Pursuit snapshot
Pro- Go / no-go verdict on every requirement
- 5 watch-outs that disqualify bidders
- The 8-item required-submittals checklist
Cancel anytime · no card to browse
Project details
The U.S. Navy is seeking proposals for the repair of a PUMP HIGH PRESSURE. The repair must meet the operational and functional requirements as defined by the CAGE code and reference number: CAGE: 0UTW4, Ref. The item must be physically marked in accordance with MIL-STD-130, Rev N, 16 Nov 2012. No substitutions are permitted without prior written approval from the NAVICP-MECH Contracting Officer. A Code 1 change (part number change only) must be reported immediately. The contractor must perform all repair work in accordance with approved repair standards, technical orders, drawings, and government or contractor-approved directives. Additive manufacturing is permitted if the vendor elects to use it; in such cases, the CDRL DD1423 reporting requirements apply, including submission of certification, data reports, and process and material traceability to NAVSUP HQ AM mailbox and WAWF. The Government requires a Repair Turnaround Time (RTAT) of 118 days from the date of physical receipt at the contractor’s facility, as reflected in the CAV system. The contractor must report all transactions by the end of the fifth business day after receipt. Government Source Inspection (GSI) is required. The Government intends to add an option quantity to the contract, which may be exercised by written notice within the timeframe specified in FAR 52.217-6. If the contractor fails to meet the RTAT and the delay is not excusable (e.g., due to Government delay), a price reduction per unit per month will be applied. The contractor must provide the price reduction amount per unit per month, up to a maximum. The Government reserves the right to terminate for default if the RTAT is not met. The contract will be awarded bilaterally, requiring the contractor’s signed acceptance prior to execution.
Key dates
- Bids due
- Dec 4, 2026
More from this agency
- Purchase of Metallic Tube for Shipboard Regulator Assembly · closes Dec 4, 2026
- 59--ANTENNA · closes Dec 4, 2026
- Procurement of O-Ring Components for Naval Use · closes Dec 4, 2026
- Repair of NRP, Flat Panel Dispenser (NSN: 3429AS4208, Part Number: ARD17-LH-001/1001408-101) · closes Dec 4, 2026
- 16--HEAT EXCHANGER,AIR · closes Dec 4, 2026
Similar bids in Pennsylvania
- Framed Metal Sloped Roof Installation for Municipal Building Maintenance Roof Portion · closes Dec 7, 2026
- Cell 9 and Phase II Closure · closes Dec 23, 2026
- VSC Phase 1 Chem Lab Relocation & Renovation Project · closes Dec 10, 2026
- Request for Proposals: 500 Tons, More or Less · closes Dec 7, 2026
- Active Adult Center Men’s Restroom Renovation · closes Dec 1, 2026
Closing soon in Pennsylvania
- Invitation to Bid: Of Engineering Services Proposals · closes Nov 30, 2026
- POWER SUPPLY · closes Nov 30, 2026
- Repair of TAC COM AND AUDIO S Equipment · closes Nov 30, 2026
- Towamensing Township Recyclable Materials Pick-Up, Transportation, and Disposal Services · closes Dec 3, 2026
- Invitation to Bid — Pittsburgh Regional Transit (PRT) Electronic Proposals · closes Dec 4, 2026