Request for Bids - E-Rate FY2027 Form 470: Cabling; Racks; Antennas, Connectors, and Related Components; Leased Equipment - Kings Co Office Of Education - KingsCOE470FY2027-C2
Kings Co Office Of EducationHanford, California#270003800
The Kings County Office of Education is soliciting proposals for a complete cabling upgrade at Shelly Baird School. The work includes replacing all legacy copper cabling with High-Performance Category 6a (Cat6a) plenum cabling, removing and disposing of all old wiring, replacing two vertical IDF cabinets with new wall-mount enclosures (Chatsworth CPI CUBE-iT®), expanding internal fiber pathways, and installing communication drops for emergency speakers, WAPs, and interactive displays. All new cabling must follow TIA/EIA 6A standards and KCOE's color-coding matrix. The contractor must provide a 10-year workmanship warranty. Proposals must be submitted in sealed packages, with one original and three bound copies, to the Business Services Department at 1144 W. Lacey Blvd, Hanford, CA 93230. A mandatory pre-bid conference and job walk is required and scheduled for November 30, 2026, at 3:00 p.m. at Shelly Baird School. Vendors must be E-Rate compliant, provide a valid SPIN and FCC-FRN, and submit a bid bond. The District may extend the contract term annually for up to four additional years.
On PublicBidSearch: the original bid posting, 2 bid documents and the agency contact (name, email and phone) for this bid.
Contact
Agency contact for this bidName, email and phone — included with ProProOverview
- Due
- Jan 8, 2027
- Time stated in bid documents
- Jan 8, 2027, 2:00 PM Pacific Time
- Bid bond
- 100%
- Performance bond
- 100%
- Payment bond
- 100%
- Submission
- mail, hand delivery
- Contract term
- 18 months from April 1, 2027, or from the start date of the project, whichever is later + The District reserves the right to extend the term annually for an add
- Documents analyzed
- 2
Steps to Bid
- 1
Review the RFP and Form 470 documents.
- 2
Attend the mandatory pre-bid conference and job walk on November 30, 2026, at 3:00 p.m. at Shelly Baird School, 959 Katie Hammond Lane, Hanford, CA 93230. by Nov 30, 2026, 3:00 PM
- 3
Submit questions in writing to [email available with Pro] by December 4, 2026, at 2:00 p.m. PST. by Dec 4, 2026, 2:00 PM
- 4
Prepare and submit a sealed proposal package, including one original and three bound copies, to the Business Services Department at 1144 W. Lacey Blvd, Hanford, CA 93230. by Jan 8, 2027, 2:00 PM
What you'll need
Contract duration
120 calendar days from the Notice to Proceed
Submission
Mail, Hand delivery
NAICS
561499, 541512
How to submit
Submit one original and three bound copies of the proposal in a sealed package marked 'KCOE-SHELLY BAIRD CABLING UPGRADE: Internal Connections, RFP NO. 2027-03'. Proposals submitted by fax or email are not acceptable.
In person/mail: 1144 W. Lacey Blvd, Hanford, CA 93230
Pursuit snapshot
Pro- Go / no-go verdict on every requirement
- 5 watch-outs that disqualify bidders
Cancel anytime · no card to browse
Project details
Request for Proposal (RFP) No. 2027-03 for the Kings County Office of Education, Hanford, CA. Scope includes: full removal and disposal of all old copper wire (Cat5, Cat5e, Cat6), replacement of two existing vertical IDF cabinets with new wall-mount enclosures meeting or exceeding Chatsworth Products (CPI) CUBE-iT® specifications (24'H x 24'W x 24'D, black finish, SKU 99565474), expansion of internal fiber pathways, and installation of supporting communication drops for InformaCast emergency speakers, Wireless Access Points (WAPs), and interactive display boards. All new Cat6a cable runs, patch cords, and jacks must adhere to TIA/EIA Category 6A standards and follow the KCOE color-coding matrix: black (cameras), white (WAPs), yellow (NMS), orange (DAC), blue (data), red (firewall), purple (clock/bell), green (lab), and grey (future expansion). All work must be routed internally through wall cavities or conduits; surface-mounted raceways are prohibited unless pre-approved. Termination must follow T568A pin-out standards. Maximum horizontal run is 55 meters (180 feet). A 10-foot service loop must be provided within 10 feet of each termination point. The District is not soliciting separate bids for Basic Maintenance of Internal Connections (BMIC) or Managed Internal Broadband Services (MIBS); these are only applicable to the proposed Internal Connections solution. The District reserves the right to reject any or all proposals and to waive minor irregularities. The work must be completed within 120 calendar days from the Notice to Proceed.
Key dates
- Questions due
- Dec 4, 2026, 2:00 PM Pacific Time
- Pre-bid meeting
- Nov 30, 2026, 3:00 PM Pacific Time
- Bids due
- Jan 8, 2027
Documents
- 22949222-USAC_FCC_FORM_470_APPLICATION_270003800_CERTIFIED.pdf6 pages
- 22948367-Shelly_Baird_RFP_2027_03_Final.pdf53 pages
Similar bids near Hanford
- As-Needed Trash, Debris, Furniture, and Appliance Removal Services · Fresno · closes Dec 29, 2026
Closing soon near Hanford
- Kings River-Hardwick School District: E-Rate FY2027 Category 1 - Internet Access and Data Transport Services · Hanford · closes Nov 30, 2026
- Support Groups and Community Support Services · Hanford · closes Dec 1, 2026
- Construction Management Software Supply and Implementation · Visalia · closes Dec 2, 2026
- Professional Services for Solid Waste Rate Study · Visalia · closes Dec 3, 2026
- 2026/2027 Tree Trimming at Various Sites · Tulare · closes Dec 5, 2026