ClosedRFP

Request for Proposals: WWTP UV Disinfection System Replacement

Town of AlpineAlpine, Wyoming

The system must meet WYPDES permit limits, including a minimum UV dose of 30 mJ/cm² and 65% UVT. The Contractor must submit a shut-down and bypass plan for approval. The Town reserves the right to reject all proposals. A bid bond of 5% of the total bid is required, and performance and payment bonds of 100% are required if the contract exceeds $100,000.

On PublicBidSearch: the original bid posting, 2 bid documents and the agency contact (name and email) for this bid.

Open Original Bid Source Pro

Contact

Agency contact for this bidName and email — included with ProPro

Overview

Due
Nov 19, 2026
Time stated in bid documents
Nov 19, 2026, 2:00 PM Mountain Time
Bid bond
5%
Performance bond
100%
Payment bond
100%
Submission
email, hand delivery, mail
Contract term
120 calendar days from Notice to Proceed
Documents analyzed
2

Scope of work

  • Replace two ULTRAAQUA MR6-220SS UV reactor systems
  • Include control panels and specified accessories
  • Ensure MBR effluent is not discharged without proper disinfection
  • Submit a UV reactor replacement shut-down and bypass operation plan for approval

Steps to Bid

  1. 1

    Submit questions by email to [email available with Pro] by November 12, 2026, at 5:00 PM MST. was Nov 12, 2026, 5:00 PM

    This date has passed — confirm eligibility with the agency before bidding.

  2. 2

    Review responses to questions, available by November 16, 2026, at 5:00 PM MST. was Nov 16, 2026, 5:00 PM

    This date has passed — confirm eligibility with the agency before bidding.

What you'll need

Submission

Email, Hand delivery, Mail

NAICS

237130, 237199

Get alerts for bids like this

New HVAC bids in Wyoming

This bid has closed. We'll tell you when the next one like it posts. Free, no card needed.

Get alerts — free

Project details

Work includes all necessary labor, supervision, equipment, tools, and materials. The Contractor must coordinate with WWTF staff for proper staging and sequencing, including a UV reactor replacement shut-down and bypass operation plan for Town approval. The system must meet the effluent limitations in the Wyoming Pollutant Discharge Elimination System (WYPDES) Permit No. WY0035611, including a minimum UV dose of 30 mJ/cm² and a design UV transmittance (UVT) of 65%. The Contractor shall procure the UV system from UltraAqua as part of the contract scope. Questions deadline: November 12, 2026, at 5:00 PM MST. Responses to questions available by November 16, 2026, at 5:00 PM MST.

Documents

  • 261102_UV_Replacement_RFP_supplemental_info.pdf45 pages
  • 261029_wwtp_uv_disinfection_sys_replacement_advertisement.pdf1 pages