CT2 & CT3 GSU Transformer Bushing Replacement at Stock Island Generating Station
Florida Municipal Power AgencyStock Island, Florida#RFP 2026-214
FMPA seeks a qualified contractor to replace bushings and current transformers on two 69 kV GE Prolec transformers at Stock Island Generating Station. The work includes full oil drain, vacuum processing, and comprehensive testing. Bidders must have five years of experience in high-voltage transformer maintenance and must submit a proposal via Vendor Link or in person by 10:00 A.M. EST on October 8, 2026.
On PublicBidSearch: the original bid posting, 4 bid documents and the agency contact (name, email and phone) for this bid.
Contact
Agency contact for this bidName, email and phone — included with ProProOverview
- Due
- Oct 8, 2026
- Time stated in bid documents
- Oct 8, 2026, 10:00 AM Eastern Time
- Submission
- electronic portal, mail, hand delivery
- Documents analyzed
- 4 published · 3 analyzed
- Required submission items
- 14 items · full checklist with Pro
Scope of work
- Replace three (3) HV and four (4) LV bushings on CT-3 GSU transformer
- Replace three (3) HV and four (4) LV bushings on CT-2 GSU transformer
- Replace seven (7) HV and seven (7) LV current transformers on CT-2
- Perform full oil drain and storage for CT-2
- Perform partial oil drain and handling for CT-3
- Conduct pre- and post-maintenance electrical and oil testing
Steps to Bid
- 1
Register on Vendor Link at Official linkPro prior to the submission date.
- 2
Submit the proposal electronically via Vendor Link or in a sealed envelope to FMPA at 8553 Commodity Circle, Orlando, FL 32819. was Oct 8, 2026, 10:00 AM
This date has passed — confirm eligibility with the agency before bidding.
- 3
Submit an Intent-to-Bid form by September 18, 2026, to receive updates and addenda. was Sep 18, 2026, 1:00 PM
This date has passed — confirm eligibility with the agency before bidding.
- 4
Submit any questions by September 18, 2026, to [email available with Pro]. was Sep 18, 2026, 1:00 PM
This date has passed — confirm eligibility with the agency before bidding.
What you'll need
Insurance
RequiredThe Contractor shall maintain the following insurance coverage: Commercial General Liability $2,500,000; Workers’ Compensation Statutory; Automobile Liability $1,000,000; Pollution Insurance $500,000; and Product Liability as set forth in the Purchase Order, if any.
Prequalification
Not requiredContract duration
The project duration is not specified in the documents. Bidders are to provide their estimated duration for CT-3 and CT-2 outages, mobilization, and total project duration.
Award method
Best value
Submission
Electronic portal, Mail, Hand delivery
NAICS
237130
How to submit
Proposals must be submitted electronically via Vendor Link (Official linkPro) or physically in a sealed envelope marked 'RFP# 2026-214, CT GSU Bushing Replacement'. Emailed submissions will not be accepted. Hardcopy submissions must be clearly marked on the outside of the sealed envelope.
In person/mail: 8553 Commodity Circle, Orlando, FL 32819
Get alerts for bids like this
New electrical bids in Florida
This bid has closed. We'll tell you when the next one like it posts. Free, no card needed.
Get alerts — freeProject details
The Florida Municipal Power Agency (FMPA) is soliciting proposals for the replacement of generator step-up (GSU) transformer bushings on two GE Prolec transformers (CT-2 and CT-3) at the Stock Island Generating Station, 6750 Front Street, Stock Island, FL 33040. The scope includes pre-maintenance testing, oil handling, bushing replacement, vacuum processing (for CT-2), post-maintenance testing, reporting, and return-to-service support. The Contractor shall provide all labor, supervision, tools, equipment, testing instruments, consumables, rigging, oil handling equipment, temporary facilities, engineering support, and project management. For CT-2, the scope includes full oil drain, replacement of three (3) HV and four (4) LV bushings, replacement of seven (7) HV and seven (7) LV current transformers, vacuum processing to less than 1 Torr, and final leak inspection. Deliverables include electrical test reports, oil analysis reports, photographic documentation, final maintenance reports, and recommendations for corrective actions. Bidders must demonstrate five (5) years of experience in power transformer maintenance, experience with 69 kV and above transformers, and NETA-certified testing personnel. Proposals must include pricing for Base Bid #1 (CT-3 bushing replacement), Base Bid #2 (CT-2 bushing and CT replacement), Alternate No. 1 (supply of CT-3 bushings), Alternate No. 2 (supply of CT-2 bushings), and Alternate No. 3 (additional vacuum processing and moisture reduction services). The proposal must be submitted electronically via Vendor Link or physically in a sealed envelope to FMPA at 8553 Commodity Circle, Orlando, FL 32819, by 10:00 A.M. EST on October 8, 2026. The RFP package is available at [link available with Pro] or via [link available with Pro].
Documents
- SI-CT-GSU-Transformer-Bushing-Replacement-RFP-FINAL.pdf45 pages
- Questions-Answers-SI-CT2-CT3.pdf1 pages
- SI-CT2-CT3-GSU-Transformer-Bushing-Replacement-RFP-2026-214-Questions-Answer.pdf1 pages
- Questions-Answers-Revision-2.pdf2 pages
Closing soon near Stock Island
- CDBG-MIT Trenchless Installation of Utilities Across Flemming Channel · Key West · closes Dec 2, 2026
- AC Repairs and Replacements · Key West · closes Dec 4, 2026