Spare Main Generator Breaker
City of AustinAustin, Texas#IFQ 1100 CPG1095
The City of Austin, Austin Energy, is soliciting quotes for one spare medium-voltage generator breaker assembly to replace existing equipment at the Decker Creek Power Station. The breaker must be new or refurbished, factory-tested, and compliant with ANSI/IEEE standards for 15 kV switchgear. The original breaker is ITE Imperial Corporation, Model 11, Serial 95757-A1-3-8A, with specified electrical and mechanical ratings. Factory Acceptance Test and commissioning support are required. All documents must be submitted digitally to designated contacts. Delivery is to 8003 Decker Ln, Austin, TX 78724-3015. The City is exempt from sales and excise tax.
On PublicBidSearch: the original bid posting, 3 bid documents and the agency contact (name, email and phone) for this bid.
Contact
Agency contact for this bidName, email and phone — included with ProProOverview
- Due
- Dec 2, 2026, 2:00 PM CT
- Time stated in bid documents
- Dec 2, 2026, 2:00 PM Central Time
- Submission
- Contract term
- 120 days
- Documents analyzed
- 3
Scope of work
- Perform Factory Acceptance Test (FAT) and provide commissioning and startup support
- Submit all deliverables digitally to Rogelio Zavala, James Cox, and Maria Bernal Mora
Steps to Bid
- 1
Review the full solicitation documents, including the IFQ PAC, IFQ Addendum, and the Scope of Work attachment.
- 2
Submit all required documents digitally to Rogelio Zavala, James Cox, and Maria Bernal Mora via email.
What you'll need
Submission
NAICS
335912, 335913
Pursuit snapshot
Pro- Go / no-go verdict on every requirement
- 3 watch-outs that disqualify bidders
Cancel anytime · no card to browse
Project details
The original breaker is ITE Imperial Corporation, Model 11, Serial 95757-A1-3-8A, with the following nameplate data: rated voltage 13.8 kV, maximum voltage 15 kV, impulse voltage 95 kV, frequency 60 Hz, rated continuous current 3,000 A, rated symmetrical MVA 11.5–15.0 kV at 1,000 MVA, rated symmetrical short-circuit current 3,850 A, asymmetrical rating factor 1.15, and control voltage 125 DC.
Key dates
- Questions due
- Dec 2, 2026, 2:00 PM Central Time
- Bids due
- Dec 2, 2026, 2:00 PM CT
Documents
- IFQ_1100_CPG1095_IFQ_PAC_1_v1.pdf14 pages
- IFQ_1100_CPG1095_IFQ_ADD_1_v1.xlsx
- IFQ_1100_CPG1095_IFQ_ATT_1_v1.pdf5 pages
More from this agency
- Professional Health Lobbyist Services for the City of Austin · closes Dec 2, 2026
- John Trevino Jr. Metro Park - Phase I Development · closes Dec 3, 2026
- North Lamar Blvd Corridor-North of Parmer Ln to Howard Ln · closes Dec 3, 2026
- Traffic Signal Cables · closes Dec 8, 2026
- Collection, Hauling, and Disposal of Waste at City Facilities · closes Dec 10, 2026
Similar bids near Austin
- Hal C. Weaver Power Plant Turbine Replacement – Construction Manager-at-Risk Selection · Austin · closes Dec 4, 2026
- Distribution Getaway Duct Bank Bore at East Village Substation · Austin · closes Dec 17, 2026
- Holiday Lighting and Decorations · Austin · closes Jan 28, 2027
- Install Generator at FCI Bastrop · Bastrop · closes Dec 10, 2026
- Electrical Repair Parts - Non Warehouse Stock · Round Rock · closes Sep 30, 2030
Closing soon near Austin
- Human Resources, Payroll, Time, Labor, and Leave Services · Austin · closes Nov 30, 2026
- External, Mock HRSA 340B Audit · Austin · closes Nov 30, 2026
- 290 Toll MBGF Upgrades (Ph II) Project · Austin · closes Nov 30, 2026
- Bike Lane Delineators and Speed Management Devices · Austin · closes Dec 1, 2026
- Lund Farms Subdivision Section 1 Phase 1B, Paving, Drainage, Water, and Wastewater Improvements · Austin · closes Dec 3, 2026