OpenRFQCloses Dec 2, 2026, 2:00 PM CT

Spare Main Generator Breaker

City of AustinAustin, Texas#IFQ 1100 CPG1095

The City of Austin, Austin Energy, is soliciting quotes for one spare medium-voltage generator breaker assembly to replace existing equipment at the Decker Creek Power Station. The breaker must be new or refurbished, factory-tested, and compliant with ANSI/IEEE standards for 15 kV switchgear. The original breaker is ITE Imperial Corporation, Model 11, Serial 95757-A1-3-8A, with specified electrical and mechanical ratings. Factory Acceptance Test and commissioning support are required. All documents must be submitted digitally to designated contacts. Delivery is to 8003 Decker Ln, Austin, TX 78724-3015. The City is exempt from sales and excise tax.

On PublicBidSearch: the original bid posting, 3 bid documents and the agency contact (name, email and phone) for this bid.

Open Original Bid Source Pro

Contact

Agency contact for this bidName, email and phone — included with ProPro

Overview

Due
Dec 2, 2026, 2:00 PM CT
Time stated in bid documents
Dec 2, 2026, 2:00 PM Central Time
Submission
email
Contract term
120 days
Documents analyzed
3

Scope of work

  • Perform Factory Acceptance Test (FAT) and provide commissioning and startup support
  • Submit all deliverables digitally to Rogelio Zavala, James Cox, and Maria Bernal Mora

Steps to Bid

  1. 1

    Review the full solicitation documents, including the IFQ PAC, IFQ Addendum, and the Scope of Work attachment.

  2. 2

    Submit all required documents digitally to Rogelio Zavala, James Cox, and Maria Bernal Mora via email.

What you'll need

Submission

Email

NAICS

335912, 335913

Pursuit snapshot

Pro
  • Go / no-go verdict on every requirement
  • 3 watch-outs that disqualify bidders
Unlock with Pro — $20/mo

Cancel anytime · no card to browse

Project details

The original breaker is ITE Imperial Corporation, Model 11, Serial 95757-A1-3-8A, with the following nameplate data: rated voltage 13.8 kV, maximum voltage 15 kV, impulse voltage 95 kV, frequency 60 Hz, rated continuous current 3,000 A, rated symmetrical MVA 11.5–15.0 kV at 1,000 MVA, rated symmetrical short-circuit current 3,850 A, asymmetrical rating factor 1.15, and control voltage 125 DC.

Key dates

Questions due
Dec 2, 2026, 2:00 PM Central Time
Bids due
Dec 2, 2026, 2:00 PM CT

Documents

  • IFQ_1100_CPG1095_IFQ_PAC_1_v1.pdf14 pages
  • IFQ_1100_CPG1095_IFQ_ADD_1_v1.xlsx
  • IFQ_1100_CPG1095_IFQ_ATT_1_v1.pdf5 pages